Μολις αγορασα το συγκεκριμενο καλοδιο
http://www.plaisio.gr/Peripherals/Connectivity/Cables/Adapters/Turbo-X-USB-A-Male-DB9-Male-Male.htm
Και αυτο το βραδυ, μαλον θα κανω την διαδικασια αυτη .
I have been working through the service manuals and the procedure is exactly the same for all 9G models. The only slight difference are the tentative voltage setting values but I will describe these later.
I was only confident trying this fix as it is exactly the same procedure used by Pioneer service engineers when servicing the panel.
I can break it down like this. The reason the screens go grey / red is because various corrections are made by the TV (referring to the pulse-meter count) to calculate how long the panel has been used for. My method resets these corrections basically fooling the TV into thinking it has a brand new panel again. Remember that the panel is not brand new so some adjustment maybe required after the clearing procedure. I would be interested to know if it is only people using calibrated settings who have had the red tint over time?
The section below is common to ALL 9G Kuros and is straight from the service manual.
8.4 ADJUSTMENT WHEN THE SERVICE PANEL ASSY IS REPLACED
After the panel is replaced with one for service, voltage margin adjustment is required.
Basically, voltage margin adjustment is performed using the Panel Factory menu.
After the panel is replaced and the unit is turned on, clear the pulse meter first.
For details on how to clear the pulse meter, see "8.3 HOW TO CLEAR HISTORY DATA".
∗1: As various corrections are made referring to the pulse-meter count to calculate how long the panel has been used, if adjustment of the panel for service is performed without clearing the pulse-meter count, proper adjustments will not be performed.
∗2: The drive sequence for Video 60-Hz is used for adjustment. When adjustment is made using the Panel Factory menu, the current drive sequence is displayed on the screen, as shown in the figure below. Make sure that 60VS is always indicated during adjustment.
Procedures for resetting corrections for change over time:
Turn the unit on. / [PON]
Enter Factory mode. / [FAY]
Set PM/B1-B5 to CLEAR (to clear the pulse meter). / [CPM]
Set HR-MTR to CLEAR (to clear the hour meter). / [CHM]
Turn the unit off. / [POF]
∗ To reflect the results of log clearing for each correction function,
the unit must be turned off then back on again. Before adjustment,
be sure to turn the unit off then back on again.
The next part of the section regards the tentative voltage settings. These do vary slightly depending on which model you have. Only change these using the remote and only if you have issues after clearing. These tentative settings are a safe default if you get stuck. Where it says "indication value", these are the values you already have so no need to change them.
Procedures for stabilizing the panel before adjustment:
Turn the unit on. / [PON]
Enter Factory mode. / [FAY]
For 5020FD / LX5090
Setting Item Tentative Setting Value
VOL SUS / [VSU ∗∗∗] 128
VOL OFFSET / [VOF ∗∗∗] VOF indication value
VOL RST P / [VRP ∗∗∗] VRP indication value
VOL XPOFS1 / [VX1 ∗∗∗] 085
VOL XPOFS2 / [VX2 ∗∗∗] 047
VOL YNOFS1 D / [V1F ∗∗∗] V1F indication value
VOL YNOFS3 D / [V3F ∗∗∗] V3F indication value +0
VOL YNOFS4 D / [V4F ∗∗∗] V4F indication value
VOL YNOFSA D / [VYF ∗∗∗] 128
For 101FD / 500M
Setting Item Tentative Setting Value
VOL SUS / [VSU ∗∗∗] 128
VOL OFFSET / [VOF ∗∗∗] VOF indication value
VOL RST P / [VRP ∗∗∗] VRP indication value
VOL XPOFS1 / [VX1 ∗∗∗] 085
VOL XPOFS2 / [VX2 ∗∗∗] 063
VOL YNOFS1 D / [V1F ∗∗∗] V1F indication value
VOL YNOFS3 D / [V3F ∗∗∗] V3F indication value +0
VOL YNOFS4 D / [V4F ∗∗∗] V4F indication value
VOL YNOFSA D / [VYF ∗∗∗] 128
6020FD / LX6090 / 600M
Setting Item Tentative Setting Value
VOL SUS / [VSU ∗∗∗] 128
VOL OFFSET / [VOF ∗∗∗] VOF indication value
VOL RST P / [VRP ∗∗∗] VRP indication value
VOL XPOFS1 / [VX1 ∗∗∗] 105
VOL XPOFS2 / [VX2 ∗∗∗] 063
VOL YNOFS1 D / [V1F ∗∗∗] V1F indication value
VOL YNOFS3 D / [V3F ∗∗∗] V3F indication value +0
VOL YNOFS4 D / [V4F ∗∗∗] V4F indication value
VOL YNOFSA D / [VYF ∗∗∗] 128
It is interesting that there is a difference between 5020/5090 and 500M in the VOL XPOFS2 value only, but this doesn't apply to the 60" TVs.
The most interesting value is VOL RST P which seems to concern black levels and is the one Pioneer themselves adjusted on mascior's TV. If you adjust to low you get sparkles (although I didn't), to high and the MLL or black luminence is raised and you can see the black turn to grey again. If you have an issue of too much black, raise VOL RST P but don't raise it too high or you will lose your inky blacks.
I personally don't think it is possible to brick the TV with voltage margin adjustments but I cannot guarantee this and you do it at your own risk. I have had VOL RST P down to 010 and up to 118 without issue.
I have set all my voltages to the tentative values apart from VOL RST P which I have raised to 062. The picture is now perfect and I tested it for 6 hours straight last night (Alien Anthology). No artefacts, no sparkles, no excess heat and bezel matching blacks